Phenolic Fiberglass Grating

phenolic grating heat testedMarco Fiberglass phenolic grating is approved by U.S. Coast Guard by surpassing both level 2 and level 3 tests. The USCG test requires sample grating to be exposed to 1700℉ (927℃) for one hour as per ASTM E-119. The sample that we supplied carried 140 psf uniformed load during the test, exceeding the requirement of 94 psf by a factor of 1.49.

phenolic grating heat tested

 

 

U.S. Coast Guard Approved Molded Grating:

Marco Fiberglass provides only one style of USCG molded grating: phenolic superspan 1.5" x 1.5" x 6". The grating can be used in cases where more pipe penetration or cutout is required. phenolic molded grating

  • Corrosion Resistance
  • Easy Installation and Maintenance
  • Extreme Fire Resistance
  • Light Weight

 

ID Height Mesh Size Load Bar Width Opening Approx. Weight Full Size
PHM-1.5-1.5.-6 1.5" 1.5" x 6" 0.6" 55% 3.90 lbs/sf 4' x 12' 0.5"

 

U.S. Coast Guard Approved Pultruded Grating:

Marco Fiberglass offers only one style of USCG pultruded grating: phenolic I-beam 1.5" -60%. The grating can be used in cases where greater span is required owing to environment or construction.phenolic pultruded grating

  • Unidirection Strength
  • Easy Installation
  • Superior Corrosion Resistance
  • Impace Resistance

 

 

ID Height Load Bar Centers Load Bar Width Opening Cross Bar Spacing Approx. Weight
PHI-15-60 1.5" 1.5" 0.6"  60% 6" 3.06 lbs/sf

 

USCG Phenolic Grating

What is USCG test?

FRP gratings are not specifically addressed in the individual vessel regulations. However, the resins typically used in the manufacture of these gratings are combustible and heat sensitive; therefore, FRP gratings use must be limited based on the requirements discussed below.

These requirements are not intended to eliminate any other design criteria or requirement pertaining to the material, construction, or performance of the FRP gratings in the non-fire condition.

Level 1 (L1): FRP gratings meeting the L1 performance criteria are intended to be satisfactory for use in escape routes or access for firefighting, emergency operation or rescue, after having been exposed to a significant hydrocarbon or cellulosic fire incident. In addition they are also acceptable for the services and functions described for levels L2 and L3.

Level 2 (L2): FRP gratings meeting the L2 performance criteria are intended to be satisfactory for use in open deck areas where groups of people are likely to assemble such as temporary safe refuge or lifeboat embarkation areas. In addition they are also acceptable for the services and functions described for level L3.

Level 3 (L3): FRP gratings meeting the L3 performance criteria are intended to be satisfactory for use in egress routes and any areas that may require access for firefighting, rescue or emergency operations during exposure to or shortly after exposure to a transitory hydrocarbon or cellulosic fire.

Contact one of our sales representatives today
to inquire about a quote from Marco Specialty Steel, Inc.